| The utility room fan shall have axial impellers and a maintenance free motor with thermal protection. The case shall be of high gloss ABS. The fan shall be capable of extracting 162m³/h (45l/s) at free air and meeting Building Regulations when installed. It should be suitable for 230 volt operation and double insulated. Control options should include timer and condensation control PCB's with a glass fibre content. All fans and ancillaries to be manufactured by Silavent Ltd, 60 High Street, Sandhurst, Berkshire, GU47 8DY. |
|
Extract 120
| Product Code |
Description |
Fixing |
| EXT 120 |
Standard |
Wall/ceiling |
| EXT 120P |
Pull cord |
Wall |
| EXT 120T |
Timer |
Wall/ceiling |
| EXT 120HTP |
Condensation control / timer and pull-cord override |
Wall/ceiling |
|
|
|
|
|
|